SBL-STJ-00119



Applies to:


Siebel System Software - Version: 8.0.0.5 [20420] - Release: V8
Siebel CRM - Version: 8.0.0.5 [20420] - Release: V8



Symptoms


Unable to perform slipstream patch installation in unattended mode
because installer prompt for terminate existing Siebel server process
even if there is no Siebel processes left. When try to use and install
with recorded response file, the installation utility exit with the
following error in the error log file.

Please stop the server manually and run patch installation again.(SBL-STJ-00119)


Cause


As per the logs and in-house test, the patch installer detect that there
are Siebel process running hence prompt the message and error. If
server is stop and no Siebel related process running, the prompt will
not appear.


Solution


Verify all the Siebel processed stopped and follow step per MR guide closely before launching the patch installer again.




1) Stop all ruunig Siebel Server with stop_server on each
applicable server machine. Also make sure shut down and exit from any
running instances of the Siebel Server Manager (srvrmgr) session.

2)
If you are patching an instance of Siebel Management Agent that was
previously installed with a Siebel Server, also stop the service for the
Management Agent.

3) Unload libraries from the system cache by running the command reset_server all on each applicable server machine.

4) Stop the Siebel Gateway Name Server by running the command stop_ns.

5) Stop the Web server with the respective commands.

6)
Specifically for AIX only, verify that the login ID performing
installation has permission to run slibclean by asking the administrator
to change the permission as follows:

chmod 6555 /usr/sbin/slibclean

7) For AIX only, execute slibclean, as follows:

/usr/sbin/slibclean






Applies to:


Siebel System Software - Version: 8.0 [20405] to 8.1.1.3[21219] - Release: V8 to V8
Microsoft Windows (32-bit)



Goal



How to install a SWSE 8.0.x - 8.1.x Fix Pack on a shared-application IIS Web Server without stopping it.





Solution



Below are the steps which should first be executed in a non-production,
test environment, assuming the siebel server components are already
patched to the target version and the SWSE is still running at the
previous version.  This example assumes that SWSE fix pack
8.1.1.2[21215] is being installed on top of 8.1.1[21112] fix pack in a
shared-application IIS Web Server and the configured application/web
site is for Call Center.




NOTE: This process further assumes that IIS
Application Protection is set "High (Isolated)" for the Siebel
application. This assures that the SWE library will be running in a
separate memory space, and thus by shutting-down the Siebel application
pool the SWE library will not be locked by the Windows operating system
and will be successfully replaced by the patch installer.



1)
Locate network SWSE 8.1.1.2 patch installer folder on the network, copy
its installer response file (siebel.ini) locally and rename it (this
example assumes C:\swse_siebel.ini) for modification.

2) Using the Windows IIS ADMIN utility:

a) Stop Siebel application pools
b) Stop Siebel web sites (call center)
c) Confirm IIS ADMIN HTTP service is running
d) Confirm WWW Publishing service is running


3) Using a standard text editor, modify and save changes to C:\swse_siebel.ini as follows:



[RunBeforePatch]
StopWebServer = no

[Behavior]
StopServers = no
AbortOnFail = no



4) Install the 8..1.1.2 SWSE fix pack using the modified swse_siebel.ini
For example: Z:\SBA8112_Network_Installer_Image_Directory\SWEApp\setup.exe -args SS_SETUP_INI=C:\swse_siebel.ini




NOTES:
a) When prompted to shutdown the Web Server, choose "NO".
b) When error "SBL-STJ-00119" is displayed, choose "OK" to continue with the install process (ignoring the error).



5) After the installation has completed successfully, restart services in this order:

a) IIS ADMIN application pools for Siebel Server
b) IIS ADMIN Web Site for call center
c) Siebel gateway
d) Siebel server



NOTE: At this point, the 21215 directory is not visible in IIS ADMIN
and not available in the $SIEBEL_ROOT\SWEApp\PUBLIC\enu directory

6) Open a new browser instance (thin client) and point to URL: http://localhost/call_center_enu




NOTE: At this point, there is a pause while the
21215 folder is created in $SIEBEL_ROOT\SWEApp\PUBLIC\enu folder (pulled
from the Web server).



a) Log into the call
center application (thin client) and wait for it to display the first
view. There will be a slight delay at this point while the 21215 folder
is created for the SWSE.
b) Refresh the IIS ADMIN default web site view (callcenter_enu) and you should see that the new 21215 SWSE folder is visible.
c) Check $SIEBEL_ROOT\sweapp\public\enu folder now contains 21215 folder.
d) In call center, check Help > Technical Support, which should display: 8.1.1.2 21215 ENU(*).


7)
Confirm that none of the non-Siebel shared IIS applications have been
affected by this process. Once you confirm this process has no negative
effects on Siebel and/or non-Siebel applications which share the IIS
Web Server, this process may be repeated with care into similar
environments.


תגובות

פוסטים פופולריים מהבלוג הזה

Profile Attributes and Open UI

SBL-BPR-00191: The rowId of the active row of the primary buscomp '%1', '%2', does not match the Primary Id

SBL-SVC-00150