SBL-SMI-00151: System component initialization timed out. System will shut down.



Applies to:


Siebel System Software - Version 8.0 [20405] to 8.2.2.2 SIA[23016] [Release V8]
Information in this document applies to any platform.

Error Message Area:Server Management Infrastructure - SMI

Version:Siebel 8.0

***Checked for relevance on 20-Feb-2013***





Purpose


This document is intended to provide cause and corrective action
information about Siebel Error Message SBL-SMI-00151: System component
initialization timed out. System will shut down.



Scope


This document is informational and intended for any user.



Details



Explanation


Startup of system components timed out.



Corrective Action


Check the server log file for any errors related to system
components. If there are no errors or a system component is expected to
take a long time to start, increase the Component Priority Level Timeout
parameter.








Applies to:


Siebel eCommunications - Version: 8.0.0.3 [20416] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms



==== ODM Issue Clarification ====



On : 8.0.0.10 [20436] version, System Admin



When attempting to start siebel apps server after patching to 8.0.0.10,

the following error occurs.



ERROR

-----------------------

GenericLog GenericError 1 000092164eeab1a0:0 2011-12-15 20:36:11
(sccnmsys.cpp (1305) err=2883609 sys=0) SBL-SCC-00025: No value found in
the Gateway. Default value in the repository is used.

ror 1 0000369c4eea7146:0 2011-12-15 20:54:48 (schedule.cpp (944)
err=1376408 sys=0) SBL-SMI-00152: TIMEOUT Component initialization
for priority level 2 timed out after 300 s.

GenericLog GenericFatal 0 0000369c4eea7146:0 2011-12-15 20:54:48
(schedule.cpp (955) err=1376407 sys=0) SBL-SMI-00151: System component
initialization timed out. System will shut down.



STEPS

-----------------------

The issue can be reproduced at will with the following steps:

1. Patch from 8.0.0.3 to 8.0.0.10FP

2. Start enterprise

3. Not starting the enterprise






Cause



After further investigation, it was found that home directory for
the siebel user was pointing to a wrong directory path other than the
directory having the siebel server installed




Solution


Resolution steps :



1. Home directory for the siebel user must point to same directory where siebel installed

2. Once point to correct directory restart the enterprise

תגובות

פוסטים פופולריים מהבלוג הזה

Profile Attributes and Open UI

SBL-BPR-00191: The rowId of the active row of the primary buscomp '%1', '%2', does not match the Primary Id

SBL-SVC-00150