SBL-BPR-00186: Step '%1' references non-existent error symbol '%2'.

Applies to:


Siebel System Software - Version: 7.0.4 [14068] and later   [Release: V7 and later ]
Information in this document applies to any platform.

Area(s):ADM - App. Deployment Manager, Siebel EAI

Release(s):V7 (Enterprise), V7 (Professional)

Database(s):All Supported Databases

App Server OS(s):All Supported Platforms

Latest release tested against:V7 (Enterprise)

Keywords:Application Deployment Manager, ADM, UDA, EMT



This document was previously published as Siebel Troubleshooting Steps 41.


Purpose


How To Troubleshoot Application Deployment Manager (ADM) in Siebel 7.7.

Last Review Date


05-Jan-2006

Instructions for the Reader


A Troubleshooting Guide is provided to assist
in debugging a specific issue. When possible, diagnostic tools are included in the document
to assist in troubleshooting.

Troubleshooting Details



The information presented in this document is intended to help troubleshoot ADM related problems and the most commonly reported symptoms and error messages while running Application Deployment Manager (ADM). ADM is a new feature in Siebel version 7.7 that helps Siebel administrators easily and quickly automate the migration of key reference data across different Siebel environments, such as between a development and a test environment. This troubleshooting document is a supplement to Siebel Bookshelf version 7.7 > Going Live with Siebel eBusiness Applications > Migrating Customizations Between Applications.



Note: This document may not be fully applicable for Siebel version 8.x due to the new ADM architecture, for more information please review Siebel Application Deployment Manager Guide from version 8.x.

 

 






















































Contents


Troubleshooting Overview



Table 1 - Deployment Session Status Field Values


Table 2 - Component Events to Enable for ADM Troubleshooting


Figure 1 - Location of Log Files for ADM errors


Table 3 - ADM Session Log.


Architecture



Figure 2 - Siebel Components and Objects Used in ADM


ADM Workflow Processes for Online Deployments



Figure 3 - Workflow Process and Business Services Used for Online Deployment


ADM Business Services for File Deployments



Figure 4 - Business Services Used for File Deployment


Common ADM Error Messages



Table 4 - Common ADM Error Messages and Symptoms


Figure 5 - Hierarchical LOV Deployment with LOVs of the Same LOV Type


Figure 6 - Hierarchical LOV Deployment with LOVs of Different LOV Type



 

 

Troubleshooting Overview


 

Because ADM is designed with standard Siebel Business application components and objects, many tools already exist for troubleshooting the individual Siebel components. The challenge is to understand how the components communicate with each other and the sequence of events. An understanding of the ADM architecture and workflow processes is critical to successful isolating and resolving problems.

 

The general steps for troubleshooting are:

 


  1. Navigate to Site Map > Application Deployment Manager > Deployment Session View View and locate your ADM session’s status. The status will let you know if there is an error. See Table 1 for an explanation of the session statuses and first steps.


 


  1. Check the source and target systems for log files or error messages. The locations where logs can be found are shown in Figure 1. Log file locations for the Siebel server and a dedicated client are shown. If you are performing an online deployment OR a file deployment connected to a thin client, the logs you want to examine will be on the Siebel server. If you are performing a file deployment on the dedicated client, the logs you want to examine will be on the dedicated client.


 


  1. Once you have found the relevant log files, scan the component logs to find the first point of failure. Typical error messages for ADM are listed in this Troubleshooting guide.


 


  1. If the logs do not contain any detail, enable the appropriate component events for each server component. See Table 2 for a list of the component events to enable and which components to enable them on.


 


  1. If you identify the problem to be related to an integration object, business component rules or the EAI Siebel Adapter, then do further testing using export files.


 

Once you have resolved the problem, re-create your ADM session and deploy it again.

 

Table 1 - Deployment Session Status Field Values

 














































Status


Description


Diagnostic


New


This is a new deployment session.


Deployment session has not submitted yet.


Submitted


This is a status that you will usually see for HTTP deployments. This means data has been sent successfully sent from the source system to the target system.


On the Source system, you will see the Submitted status until the jobs complete on the Target system.

 

If the status never changes on the source system, check target system for queued or failed server requests (jobs). Typically these requests will be in the WorkFlow Process Manager server component. To find the jobs, navigate to Site Map > Administration - Server Management > Jobs.

 

On the target system, also make sure the Workflow component group is online, and you have synchronized the batch components.


Validation Failed


This status indicates that the source system was unable to validate the environment details (see error SBL-SVC-00232) or log into the target server.


Check the source system log file in the $SIEBSRVR/temp/<session_id>.log for the underlying error message.


Deployment Failed


The deployment failed.


Check the source system log file in the $SIEBSRVR/temp/<session_id>.log for the underlying error message.

 

If it was an online deployment, also check target system for Workflow or EAI object manager logs for any errors.


Incomplete Deployment


Some items did not deploy successfully. Other items may have been deployed successfully.


Check the source system log file in the $SIEBSRVR/temp/<session_id>.log for the underlying error message.

 

If it was an online deployment, also check target system for Workflow or EAI object manager logs for any errors.


Export Completed


This is a status usually for file deployments. It indicates a successful file export.


The ADM data was exported successfully from the source system. Check the specified file directory for the output file.

 

NOTE: this status does not indicate that data was imported into the target system.


Deployment Completed


This status indicates successful data migration from source to target.


The submitted deployment ran successfully on the target system, and an acknowledgement was successfully sent back and received.



 

 

Table 2 - Component Events to Enable for ADM Troubleshooting

 






































































































Component Event Name (Alias)


Level


Description


Components*


ADM Event (ADM Event)


4


Captures events related to ADM, such as errors.


EAIObjMgr, WfProcMgr, the AOM


EAI Siebel Adapter (EAISiebAdpt)


4


Captures EAI Siebel Adapter related events, including integration component and integration component fields accessed, and the values for the fields; business components and business component fields accessed and the values for the fields.


WfProcMgr, the AOM


EAI Transport (EAITransport)


4


Captures EAI Transport related events: including direction (send/receive) and result. For HTTP transport, shows headers and responses. For File Transport, shows the full filename.


EAIObjMgr, WfProcMgr, the AOM


Performance Event (FSMPerformance)


4


Captures events related to the File Systems performance such as time taken to read or write to the file system, and the name of file.


EAIObjMgr, WfProcMgr, the AOM


Event Context (EventContext)


4


Captures applet and method executed, view names, and screen names that the user navigates to.


the AOM


SrmBusSvc Condition (SRMBusSvc)


3


Captures when the Server Requests business service submits a job.


EAIObjMgr, WfProcMgr, the AOM, SRProc, SRBroker


Server Requests Routing Info (SRMRouting)


4


Captures Server Requests routing information, including SRB Session ID and component name.


EAIObjMgr, WfProcMgr, the AOM, SRProc, SRBroker


Object Manager SQL Log (ObjMgrSQLLog)


4


Captures the SQL select, insert, update, and delete statements.


EAIObjMgr, WfProcMgr, the AOM


Session Manager (SessMgr)


3


Captures SISNAPI events related to the Siebel session manager.


WfProcMgr, the AOM


Object Manager Business Service Operation and SetErrorMsg Log (ObjMgrBusServiceLog)


4


Captures Business Service-related events such as when business services are created, deleted, and the methods invoked.

 


EAIObjMgr, WfProcMgr, the AOM


Object Manager Business Component Operation and SetErrorMsg Log (ObjMgrBusCompLog)


4


Captures Business Component-related events: create and delete.


EAIObjMgr, WfProcMgr, the AOM


Workflow Engine Invoked (EngInv)


4


Captures when the workflow process engine is invoked.


EAIObjMgr, WfProcMgr


Workflow Process Execution (PrcExec)


4


Captures workflow process related events, and shows process properties values.


EAIObjMgr, WfProcMgr


Workflow Step Execution (StpExec)


4


Captures the process step events including business services invoked and inputs and outputs of the business services, conditions evaluated, and outcome of the step.


EAIObjMgr, WfProcMgr


XML Conversion (XMLConversion)


4


Captures the conversion of XML documents to property sets steps and vice versa, shows encoding used in the document.


EAIObjMgr, WfProcMgr



 

* AOM refers to your application object manager. If you are connected through the Siebel Web Client, you are using an application object manager, such as CallCenter (SSCObjMgr_enu).

 

You can enable more events than those listed in Table 2. The events listed in Table 2 are intended as a starting point for troubleshooting generic ADM problems. For more information about the component event infrastructure, refer to Siebel Bookshelf version 7.7 > System Monitoring and Diagnostics Guide for Siebel eBusiness Applications > Configuring Siebel Server and Component Logging > Configuring Siebel Server Component Logging.

 


Figure 1 - Location of Log Files for ADM errors

 


 

 

On the source system, the ADM log file in the $SIEB_ROOT/temp directory often contains more information than you will see on the screen. The ADM Session will show a hyperlink to the log file. Even if you do not see a file listed in the ADM Session, check the Siebel server temp directory for a file.


A sample log where a deployment failed and the reason it failed is shown below in Table 3. The filename will be the name of the deployment session with a .log suffix.

 

Table 3 - ADM Session Log. Filename Is 42-4P84F.log

 














































































Line #


Text


1


[Deployment Session Header]


2


ADM Deployment Session: 42-4P84F


3


ADM Deployment Project: testtest


4


Start Time: 08/01/2004 17:00:00


5


Target Web Address: http://myserver/eai_enu


6


Target User Name: SADMIN


7


 


8


[Transaction: ProdFeature]


9


Status: Data Preparation Completed


10


Session Items: UDA Admin Product Line, UDA Product Feature


11


End Time: 08/01/2004 17:00:07


12


 


13


[Transaction: ProdFeature]


14


Status: Import Failed


15


End Time: 08/01/2004 17:00:17


16


EAI Logs:


17


No inserts are allowed in Integration Component 'Admin Product Line_Internal Product'.

(SBL-EAI-04184)



 

In the sample ADM Session log, you can see the name of the ADM project testtest in line 3, as well as the target server name myserver in line 5. You can also quickly see that the deployment data type, ProdFeature in line 8 and line 13, and the final status Import Failed in line 14.  The Status Data Preparation Completed on line 9 means that the source system was able to successfully query and get information from the Source system. But then the import into the Target system failed as shown by the status in Line 14. The failure error message is in line 17.

 

At this point, you should check the Target system for WfProcMgr logs (workflow process manager tasks) where the EAI Siebel Adapter is used to update or insert the data. In this case, the reason is because the standard Admin Product Line Internal Production integration component does not allow inserts. In order to successfully deploy the Product Feature data, the products associated with the Product Lines must already exist on the target system.

 

Architecture
 

ADM is built on the Server Requests, Workflow Process and Enterprise Application Integration (EAI) infrastructure.

 
Figure 2 presents a logical overview of the different components involved. There are two environments shown, a source and target. Each environment is a distinct Siebel enterprise with its own Siebel database and server(s). The Siebel database for each environment contains tables that store data that is to be migrated (i.e. LOV data), ADM workflow process definitions, job details for the server requests, and entries in the EAI Queue. Each Siebel enterprise has an SRF which contains the ADM integration objects. Each enterprise will also have access to its own Siebel FileSystem, which will temporarily store files used in the ADM session.

 

On the source system, you need to have the Workflow and System Management component groups online. On the target system, you need to have the EAI, Workflow and System component groups online; you also need to setup the Siebel Web Server so that the target system can receive the HTTP requests. (If you are deploying using Export file, you would not use the Siebel server components or the Web Server, but all the other components below the dashed line are still required.)

 

Figure 2 - Siebel Components and Objects Used in ADM

 


 

 

 

 

ADM Workflow Processes for Online Deployments


 

The workflow processes used by ADM and standard integration objects’ names start with the letters UDA (for Universal Deployment Agent). The primary business service used in the UDA workflow process is the UDA Service. The sequence of events, workflow processes and business services for an online ADM session are outlined in Figure 3. Because of differences in the flow and architecture for a deployment using export files, that process is outlined separately in Figure 4.

 

Figure 3 - Workflow Process and Business Services Used for Online Deployment

 


 

 

Figure 3 also illustrates the flow of data in an online deployment. When you click Deploy in the ADM views, the button invokes the UDA Deployment workflow process. The UDA Deployment workflow process runs in the current application object manager you are using. So for example, if you are logged into the Financial Services object manager, it will run in the FinsObjMgr_enu component. The UDA Deployment workflow process then runs a subworkflow process, UDA Environment Verification, to verify that the Target environment is up and its schema versions match those in the Source environment. The UDA Environment Verification workflow processes use HTTP at this point to communicate with the Target system.

 

On the target system, the EAI Object Manager receives the request from the UDA Environment Verification workflow process through the UDA Deploy named subsystem. The UDA Deploy named subsystem dispatches the request to the UDA Service business service and the UDA Service sends a response back to the source system.

 

After verification is complete, on the source system, the UDA Deployment workflow process uses the Server Requests business service to submit an asynchronous workflow process job. The workflow process task invokes the UDA Data Query workflow process. The UDA Data Query workflow process uses the EAI Siebel Adapter and method query to extract data that to be deployed (into a Siebel integration object and then into XML). Once the ADM data is obtained, it is sent from the source to the target system using the UDA HTTP Transport workflow process as a sub workflow process.

 

On the target system, the EAI Object Manager receives the ADM data from the UDA HTTP Transport workflow process through the UDA Deploy named subsystem. This time UDA Deploy named subsystem uses the Server Requests business service to submit an asynchronous workflow process job. A new workflow process manager task runs the UDA Target Workflow workflow process. In the UDA Target Workflow, the EAI Siebel Adapter, with method Upsert (in Siebel version 7.7), is used for the logic of determining if the data will be updated or inserted. Upon successful processing of the ADM Data, the workflow process manager sends a confirmation back to the source using the SISNAPI protocol.

 

On the source system, the confirmation request is received by the same application object manager that originally initiated the deployment. The UDA Acknowledgement workflow process runs to update the ADM Session data with the results from the target system.

 

ADM Business Services for File Deployments


 

Figure 4 illustrates the flow of data in a deployment using export files. Unlike batch or online deployments, when you use export files, you do not need to have a running Siebel server. There are also no explicit workflow processes invoked. The architectural simplification makes the file deployment option ideal for testing ADM.

 

If you encounter an error performing an online deployment, switching your test case to a file deployment is a good way to isolate the root cause of the error. When you test with the file deployment option on a dedicated client, you can enable client-side tracing so you can see more details on what may be happening with the underlying Siebel application layers. You can focus on errors specific to the integration objects, content objects or EAI Siebel Adapter, and not be concerned with Siebel server infrastructure. For steps on how to perform client logging, refer to How Should Client Side Logging Be Set? (Doc ID 475587.1).

 

 

Figure 4 - Business Services Used for File Deployment

 


 

 

In Figure 4, the application object manager represents the object manager engine in a dedicated client or in a zero foot print client. In a file deployment, you need to create an XML file that represents the ADM data first in the source system. The file needs to be saved in a location that is accessible by both the source and the target environments.

 

On the target system, you import the file created from the source system. When the XML file is deployed on the target system, a copy of the XML file is saved in the EAI Queue. When the update or insert is complete on the target system, a broadcast message is displayed on the target system to the position of the user who initiated the import

 

On the source system, you will still need to create an ADM project and a new ADM Session. However, when you click the Deploy button in a File deployment scenario, no workflow processes will be dispatched. Instead, the UDA Service will provide the logic to create an XML file containing the ADM deployment data.  On the target system, you can directly import the XML file using the Menu -> Deploy from File option. You do not need to have the EAIObjmgr running or any deployment session or project created on the target system.

 

The drawback to using file deployment is that you will not have a record showing if an import succeeded or failed on the source or target system. Since there is no HTTP or SISNAPI established between the target and source environment in a file deployment, there is no ADM view that shows if the deployment data was successfully imported. If there is a failure on the target system to import the data, you will see the message in the client GUI. You can also check the EAI Queue (under Application Administration – Integration) for a status and a copy of the XML that you attempted to import.

 

The file deployment mode is also supported via the server manager (srvrmgr) command line which optimizes the import operation. With one srvrmgr command, you can import multiple files.

 

Common ADM Error Messages


 

Below is a list of common ADM error messages. Make sure to search SupportWeb with the error message and check for the latest ADM alerts as well.

 

These error messages may appear on the GUI or in a log file. For a listing of places to check for log files that would contain ADM related errors, see Figure 1.

 

Table 4 - Common ADM Error Messages and Symptoms

 






















































An error occurred exporting to file. Please make sure the path <path value> points to a valid directory which has enough space and is writable by the application process owner (SBL-SVC-00255)


SBL-SRQ-00103: Unable to find definition of component WfProcMgr


SBL-SVC-00232: The schema and SRF of the source environment and the target environment must be of the same version.


Step '<?>' references non-existent error symbol '<?>'.(SBL-BPR-00186)


EAI Queue Entry Always Created During File Import


Unable To Deploy: Target Server Path is a required field. Please enter a value for the field. (SBL-DAT-00498)


Deployment Failed: “[Microsoft][ODBC Driver Manager] Invalid cursor state”


Cannot connect to the server (SBL-EAI-04115). An error occurred connecting to the Target System.


SBL-BPR-00158: Cannot execute workflow process definition 'UDA Batch Deployement'


ObjMgrSRFLog Warning...(objdef.cpp (2192)) SBL-DAT-00144: Could not find 'Import Object' named 'EMT Session'


Multiple matches found for instance of integration component '%1' using search specification '%2' in the business component '%3', based on user key '%4'


LAST_UPD_BY Field Does Not Contain Correct Values


Task Status Completed but Data Not Imported


"There were more rows than could be returned. Please refine your query to bring back fewer rows (SBL-DAT-00500) (SBL-EAI-04376)


View: UDA Project Administration View does not contain applet: EMT Project Form Applet. (SBL-SVC-00254)


LOV Parent-Child Relationship Is Not Established



 

 

An error occurred exporting to file. Please make sure the path <path value> points to a valid directory which has enough space and is writable by the application process owner (SBL-SVC-00255)


 

Symptom or Error Message

 

You received the following error when exporting to a file:

 

An error occurred exporting to file. Please make sure the path <path value> points to a valid directory which has enough space and is writable by the application process owner (SBL-SVC-00255)

 

Cause

 

The export path specified is not a valid directory name or is inaccessible from the machine where the ADM process is running.

 

Diagnostic Steps

 

Verify that the file path given is valid and can be accessed from the machine where the ADM process is running.

 

Solution

 

The export path should be a shared network resource. If deploying to a file using a dedicated client, specify an export path is that is relative to the dedicated client. For example, if you are on your local Windows machine, you can specify d:\temp as your export path.

 

If deploying to a file using a zero footprint client, specify an export path is relative to the Siebel server where the object manager is running.  For example, if you are using the thin client, and connecting to a Siebel server running on Solaris, you need to specify a network path that is valid for the Solaris server, i.e. /tmp.

 

 

SBL-SRQ-00103: Unable to find definition of component WfProcMgr


 

Symptom or Error Message

 

After clicking Deploy and entering the correct password, the deployment session fails. The following error messages shows up in the Siebel component log:

 

SBL-SRQ-00103: Unable to find definition of component WfProcMgr

 

In the ADM log or on the Siebel client, you may see this error message:

 

Error encountered at workflow "<?>", step "<?>"

- No change/update is in effect.(SBL-EAI-04442)

 

Cause

 

The Workflow Process Manager Server component definition has not been synchronized from the Server Manager screen. When you synchronize components, the Siebel server updates information about your Enterprise in the S_SRM_ACTION table.

 

Diagnostic Steps

 


  1. Navigate to Sitemap > Administration - Server Configuration > Enterprises > Synchronize.


 


  1. The middle applet (Batch Component Admin) should contain a list of server components. If the list is empty, synchronization has not been done.


 

Solution

 

In the source and target environments, start a Siebel Client. Then navigate to Sitemap > Administration - Server Configuration > Enterprises > Synchronize, click Synchronize.

 

 

SBL-SVC-00232: The schema and SRF of the source environment and the target environment must be of the same version.


 

Symptom or Error Message

 

The deployment session fails with this error:

 

SBL-SVC-00232: The schema and SRF of the source environment and the target environment must be of the same version.

 

Cause

 

In Siebel versions 7.7 and 7.7.1, ADM checks the Siebel SRF and schema versions of the target environment against that of the source environment. If either the SRF or the custom schema versions are different, you will get the error.

 

Change Request 12-MAR8FT has been logged to address this product defect. It has been fixed in Siebel Fix Pack 7.7.2.1. 

 

The new behavior is that SRF version will not be validated. The custom schema version checking will be skipped but the major, minor and vertical schema versions are still checked. However, if the SRFs between the target and source environments do not have matching integration objects, the deployment would still fail.

 

Solution

 


  1. Contact Siebel Technical Support to request the latest available 7.7.2.x Fix Pack. Install the fix pack on your target and source Siebel application environments.


 


  1. If you are not able to install the fix pack, a manual workaround is available. It is to deploy using Export Files so you can modify the XML attributes. Here is how to modify the XML:


 



    1. Determine the schema and srf versions for the target system.



 



    1. Deploy any file on the target System (you will not need to import this project into any system.) Then open up the file you deployed in notepad and copy out the lines containing the SchemaVersion and SRFVersion. It will look something like this (with different values in double quotes):



 

SchemaVersion="41.57.0.69" SRFVersion="36|1074164158|1087259477"

 



    1. Modify the Export file.



 



    1. Open up the XML file created from your source system. Then cut and paste the Schema and SRF string from the target system’s XML into your source system’s XML file. When you save the source system XML file, make sure you retain the original encoding of the XML document (utf-8).



 

NOTE: Other modifications to the XML content are not recommended unless otherwise directed by Siebel Technical Support.

 

If you require a workaround for online deployments, please contact Siebel Technical Support for assistance with modifying the UDA Deployment workflow process.

 

 

Step '<?>' references non-existent error symbol '<?>'.(SBL-BPR-00186)


 

Symptom or Error Message

 

When deploying a session using the command line interface, the status of the deployment session fails with the following errors:

 

We detected an Error which may have occurred for one or more of the following reasons:

Step '<?>' references non-existent error symbol '<?>'.(SBL-BPR-00186)

 

You may see this error in the object manager log:

 

SBL-GEN-00000: Unable to load message 0xffff

 

Cause

 

Command line deployment using on-line mode is not supported

 

Solution

 

In order to deploy in command line mode, the session must be configured to export to a file by checking the Export to File flag. Batch deployment using on-line mode is not supported.

 

 

EAI Queue Entry Always Created During File Import


 

Symptom or Error Message

 

An EAI queue entry is always created when performing a file import regardless of the Business Component User Property value.

 

Cause

 

This is an expected behavior for the standard ADM configuration.

 

Solution

 

To stop entry generation in the EAI Queue, set the User Property Use EAI Queue to Never on the EMT Session business component.

 

For more information about the EAI Queue, refer to Siebel Bookshelf version 7.7 > Siebel Connector for SAP R/3.

 

 

Unable To Deploy: Target Server Path is a required field. Please enter a value for the field. (SBL-DAT-00498)


 

Symptom or Error Message

 

You are not able to deploy to a file. When you click Deploy, you may see this message:

 

Target Server Path is a required field. Please enter a value for the field. (SBL-DAT-00498)

 

Cause

 

The Export to File box must be checked to deploy to a file.

 

Solution

 

Check the Export to File box in the ADM Session.

 

If the box is grayed out, you need to recreate a new ADM Project and check the Export to File box for the new ADM Project. Then enable the new ADM Project and redeploy.

 

 

Deployment Failed: “[Microsoft][ODBC Driver Manager] Invalid cursor state”


 

Symptom or Error Message

 

After clicking Deploy, the status changes to Deployment Failed. The following error message shows up in the SRProc.log file:

 

"[Microsoft][ODBC Driver Manager] Invalid cursor state"

 

Cause

 


  1. The database is running out of the cursors.


 


  1. There are too many connected users.


 

Diagnostic Steps

 

Check the number of the cursors in the database and make sure it complies with Siebel system requirements.

 

Solution

 

If the number of cursors is too low, increase the cursor number and run the deployment again.

 

 

Cannot connect to the server (SBL-EAI-04115). An error occurred connecting to the Target System.


 

Symptom or Error Message

 

When submitting an online deployment, you receive the following error:

 

Cannot connect to the server (SBL-EAI-04115). An error occurred connecting to the Target System. Please verify the connection information. (SBL-SVC-00252)

 

Cause

 

The HTTP session from the source to the target could not be started.

 

Diagnostic Steps

 


  1. Check that you have supplied a valid Siebel URL for the target system.


 


  1. Check that you have typed in a valid username and password for the target system


 


  1. Check that the EAI object manager on the target system is online. You can verify that the EAI object manager on the target system is online by using the statspage with this URL: http://<webserver>:<port>/eai_enu/_stats.swe (substitute <webserver> and <port> with values for your environment). If the stats page comes up, you have verified that you are able to connect to the EAI Object manager and it is online.


 


  1. Check that the source and target environments have network connectivity. For example, make sure you can ping the target webserver from the source Siebel server physical machine.


 

Solution

 


  1. Fix any invalid arguments supplied and recreate the deployment session.


 


  1. Make sure that the EAIObjMgr is online on the target system.


 


  1. If there are network problems, check with your network administrator to resolve the problems (e.g., name resolution problems, firewalls in place).


 

 

SBL-BPR-00158: Cannot execute workflow process definition 'UDA Batch Deployement'


 

Symptom or Error Message

 

When executing a batch deployment, you get the error:

 

SBL-BPR-00158: Cannot execute workflow process definition 'UDA Batch Deployement'

 

Cause

 

The workflow process name is not spelled correctly or the workflow process is not activated in the Siebel Client.

 

Diagnostic Steps

 


  1. Check the spelling of your workflow process. In the symptom above, Deployement is misspelled (an extra 'e' between the 'y' and the 'm').


 


  1. In Siebel Tools, check that workflow processes have a status of Completed. In the Siebel client, verify the same workflow processes have a status of Active.


 

Solution

 


  1. Resubmit your workflow process task with the correct spelling.


 


  1. If you have enabled a workflow process in the Siebel client, stop the workflow process manager component and restart it. Resubmit your job.


 

 

ObjMgrSRFLog Warning...(objdef.cpp (2192)) SBL-DAT-00144: Could not find 'Import Object' named 'EMT Session'


 

Symptom or Error Message

 

When you enable component event logging in the Siebel server components, you see messages like these:

 

ObjMgrSRFLog      Warning    ...    (objdef.cpp (2192)) SBL-DAT-00144: Could not find 'Import Object' named 'EMT Session'. This object is inactive or nonexistent.

 

Cause

 

These are warning messages, and they are benign. You can ignore those messages. If the value after the component event is not Warning, then you should investigate if the error is fatal.

 

 

Multiple matches found for instance of integration component '%1' using search specification '%2' in the business component '%3', based on user key '%4'


 

Symptom or Error Message

 

When deploying all the out of the box LOVs, you get this error:

 

Multiple matches found for instance of integration component '%1' using search specification '%2' in the business component '%3', based on user key '%4'.

 

Cause

 

The Siebel seed data has duplicate values for LOVs.

 

Change Request 12-MPWXD3  has been logged to address this product defect.

 

Diagnostic Steps

 

Log into the database and run the following SQL statement to see if you have duplicate seed data:

 

select TYPE, NAME from S_LST_OF_VAL

where type = ‘LOV_TYPE’

group by TYPE, NAME

having count(*) > 1

 

Solution

 

Log on a Siebel Client, and go to the LOV Views. Query for the LOV Types you found running the SQL Query in the diagnostic steps. For each duplicate pair, change the display value for one of the records to make the record unique.

 

 

LAST_UPD_BY Field Does Not Contain Correct Values


 

Symptom or Error Message

 

After migrating data from the source application to the target application with different users, records are always inserted as SADMIN user ID. The LAST_UPD_BY field does not contain correct values.

 

Cause

 

Data is inserted into the target application using the Server Request Broker (SRB) and Server Request Processor components (SRP). The user stamp on the inserted records will be the user name set for the SRB/SRP components (typically SADMIN), not the user name supplied from the source application.

 

Solution

 

Create a new user ID with the same privilege as SADMIN and update the SRB/SRP components to use that new user ID.

 

 

"There were more rows than could be returned. Please refine your query to bring back fewer rows (SBL-DAT-00500) (SBL-EAI-04376)


 

Symptom or Error Message

 

When exporting data to a file, you receive the following error message:

 

We detected an Error which may have occurred for one or more of the following reasons:

Method 'NextRecord' of business component 'Feature Access' (integration component 'Feature Access') returned the following error: "There were more rows than could be returned. Please refine your query to bring back fewer rows (SBL-DAT-00500) (SBL-EAI-04376)

 

Cause

 

There is a 10K limit on the EAI transport.

 

Solution

 

Specify a search specification such as [Name] not like 'A* to reduce the number of records returned to less than 10,000.

 

If you are not in a production environment and would like to bypass the 10K limit, it is possible to do so. However, please bear in mind that there is a potential for large memory usage of the Siebel server component.

 

To bypass the default 10000K limit, set the value for the parameter "DSMaxFetchArraySize" under the "InfraDatasources" named sub-system to the number of records you expect to export. Note that this param is for a given data source and would impact all components that share the same data source so we only advise you set this value immediately prior to your export and reset it to the default after your export.

 

On a dedicated client, you can set the value by setting param MaxFetchArraySize under the individual data source section on the client’s cfg file.

 

 

Task Status Completed but Data Not Imported


 

Symptom or Error Message

 

When deploying sessions using the command line interface, the status of the workflow process task is completed. However the data has not been imported to the target environment.

 

Cause

 


  1. The UDA Batch Import and UDA Batch Deployment workflow processes have not been deployed properly.


 


  1. The FileExportPath and FileImportPath process properties are not valid.


 

Diagnostic Steps

 


  1. In Siebel Tools, check that UDA Batch Import and UDA Batch Deployment workflow processes have a status of Completed. In the Siebel client, verify the same workflow processes have a status of Active.


 


  1. Confirm the workflow processes have the correct FileExportPath and FileImportPath process property values.


 

Solution

 


  1. Deploy the UDA Batch Import and UDA Batch Deployment workflow processes in Siebel Tools. Activate the workflow processes in the Siebel Client.


 


  1. When exporting the file, verify the FileExportPath process property is set correctly for the workflow process UDA Batch Deployment. When importing the file, verify that the FileImportPath for the UDA Batch Import workflow process has a valid value. The values should be the directories which will contain the exported and imported files respectively. Both values can point to the same location.


 

NOTE: For more information about how to deploy using the command line interface, refer to Siebel Bookshelf version 7.7 > Going Live with Siebel eBusiness Applications > Migrating Customizations Between Applications > Deploying Sessions Using Command-Line Interface.

 

For more information about deploying in batch mode (running the workflow process), refer to Siebel Bookshelf version 7.7 > Going Live with Siebel eBusiness Applications > Migrating Customizations Between Applications > Reviewing the ADM Data Migration.

 

 

View: UDA Project Administration View does not contain applet: EMT Project Form Applet. (SBL-SVC-00254)


 

Symptom or Error Message

 

View: UDA Project Administration View does not contain applet: EMT Project Form Applet. (SBL-SVC-00254)

 

Cause

 

The applet might be missing in View: UDA Project Administration View

 

Diagnostic Steps

 

In Siebel Tools, query for the View UDA Project Administration View.

 

Check for all the View Web Template Item applets. Verify if the EMT Project Form Applet is there.

 

Solution

 

In Siebel Tools navigate to View and query for UDA Project Administration View and then add a View with the following information:

 

Web Template Item

Name = "EMT Project Form Applet" applet

Item Identifier = 3 or next number

Applet Value = "EMT Project Form Applet"

Applet Mode = "Edit"

 

 

LOV Parent-Child Relationship Is Not Established

 

Symptom or Error Message

 

When deploying dependent data types, such as hierarchical LOVs with the LOV-HierParent data type, both records are successfully imported in the target system, but the parent-child relationship is not established. For LOVs, after the first deployment, the child LOV does not show the parent LOV. When you redeploy the project a second time, then the parent-child relationship is established.

 

Cause

 

For dependent data types, ADM will deploy the child data type before the parent data type. When ADM deploys the child data, the parent does not yet exist so the EAI Siebel Adapter cannot set the relationship on the child to point to the parent. Hence, after the first deployment, while both data types are successfully deployed, the relationship between the two records is not established.

 

Solution

 

This is the intended behavior of ADM that all hierarchical data must be imported twice. When deploying a child record, ADM will not error out if the parent record does not exist because the picklist validation is disabled.

 

When an LOV record with a reference to a parent Language Independent Code (LIC) value is being inserted, that parent LIC value must already be present in the target system for the reference to be successfully set. However, since the Parent LIC value is in itself another LOV record, the only way to make sure that all the references are successfully established is to import the LOV values using two dependent data types both are LOV data types. Internally this will cause two deployment operations to occur, once per session item. See Figure 5 for a logical description of what happens.

 

Import pass #1 based on the LOV-HierChild session item: all LOVs will be inserted successfully. For the child LOVs that reference a parent LIC, the parent LIC field will be left blank. The UDA List of Values integration component has been configured to ignore errors on self referenced fields which are bounded to a picklist.

 

Import pass #2 based on the LOV-HierParent session item: the same LOVs will be updated. However, now any Parent LIC values referenced in the record being imported is already present in the target DB. So therefore, second import will update the LOV records previously upserted from the first deployment with the correct parent LIC value.

 

In the case where the parent and child LOVs are of different LOV Types, you can deploy the data in one deployment session by using the deployment filter. Since the ADM child data type (LOV-HierChild) is always deployed first, if you set the deployment filter for the child ADM data type to find the record for the parent LOV, the parent LOV can be inserted before the child LOV. Then set the deployment filter for the parent ADM data type (LOV-HierParent) to find the child LOV deployment record. See Figure 6 for the logical description of what happens.

 

NOTE: If you are deploying LOVs where the LOV child and parent are of different LOV types, be sure to review Document 477904.1 for information on how to obtain updated SIFs. Without the updated SIFs compiled into your SRF, you will not be able to deploy LOV data if the LOV Types are different.

 

Figure 5 - Hierarchical LOV Deployment with LOVs of the Same LOV Type

 


 

 

Figure 6 - Hierarchical LOV Deployment with LOVs of Different LOV Type

 


 


















Applies to:


Product Release: V7 (Enterprise)

Version: 7.8.2.3 [19221] KOR Com/Med

Database: Oracle 10.2.0.2

Application Server OS: Microsoft Windows 2003 Server SP1

Database Server OS: Sun Solaris 9



This document was previously published as Siebel SR 38-3400482111.

Symptoms


SBL-UIB-00112, SBL-BPR-00186

Hi, support.
I had a problem when I tested a marketing approval process.

In UInbox
Inbox Item Detail View, I approved a campaign.
and then, the Action Value of the Ulnbox Item
Task was updated to 'Approved'
but, the Active Flag of the UInbox Item Task was still
'Y'

I tested on vanilla srf.
I'll attach a screen capture.


Solution


Message 1


For the benefit of other readers:



Customer has 3-step approval for their Campaign record: submitted - first approved – final approved. They have added a approval step 'FirstApprove' for the LOV type MKTG_PLAN_APPR_TYPE and MKTG_UINBOX_ACTION_TYPE.



They observed that two items are active after first Approval step and after final approval step, the last task and the second last task has same Action Value.



From investigation, the 2 records showing the 'Approve' action, the one with Active flag check is actually reflecting the final approve Campaign. While the one without Active flag is belonging to the 'First Approve' step. This can be confirmed using the row-id (using About record), if you match the row-ids.



The issue here is that, the 2 records are showing the same Action value and even the Comment (if you entered values into the Comment field). This is misleading and I have logged a Change Request 12-1KDJNNN on this.



Thank you,

Siebel Technical Support












Applies to:


Product Release: V7 (Enterprise)

Version: 7.8.2.3 [19221] Cons Goods

Database: Oracle 9.2.0.6

Application Server OS: Microsoft Windows 2003 Server

Database Server OS: IBM AIX 5L 5.2



This document was previously published as Siebel SR 38-3198131551.

Symptoms


Hello,



We added conditions in the Territory Management Alignment Condition (TM Account Condition).



When we run the alignment with our field in the condition, if the result is null the Workflow Process Manager fail.



We have several warnings and errors in the log file including one which result of the application of the ACR 263 that you recommended in the SR 38-3155380445 about our problem of connexions.



You’ll found attached the log which generated by the failure of the workflow process manager.



Have you got some ideas to solve this problem?



Thanks in advance for your answer.



Best regards,



Amandine MONTI

+334 67 63 71 10

Solution


Message 1


For the benefit of other users:



1.    when there is no match TM will treat this as an error and throw an exception and Instantiating step definition 'Update Alignment Status to Process Failed'..

2.    since the workflow did not complete successfully thus it needed to inform of that fact. That is why the server task finished with the status = Exited.



The customer requested that when there is no object to be assigned the task should finish with the status Completed and not status Exit. A change request # 12-1I6DSG0 has been logged for this enhancement request.



Thanks,





Siebel Support



Keywords: 'Update Alignment Status to Process Failed', TM_WF_ERR_PROCESS_FAILED', SBL-BPR-00186, SBL-OMS-00203, TM




תגובות

פוסטים פופולריים מהבלוג הזה

SBL-BPR-00191: The rowId of the active row of the primary buscomp '%1', '%2', does not match the Primary Id

Profile Attributes and Open UI

FINS Data Transfer Utilities