SBL-GEN-05043: The specified user does not have the proper privileges to connect to the name server.





Applies to:


Siebel System Software - Version: 8.1 [21039] and later   [Release: V8 and later ]
Information in this document applies to any platform.

Error Message Area:Generic - GEN

Version:Siebel 8.1



Purpose


This document is intended to provide cause and corrective action
information about Siebel Error Message SBL-GEN-05043: The specified user
does not have the proper privileges to connect to the name server.


Scope


This document is informational and intended for any user.


SBL-GEN-05043: The specified user does not have the proper privileges to connect to the name server.



Explanation


Need a Siebel administrator username and password to connect to the Siebel gateway server.
For example, "SADMIN" is an example of administative user account.


Corrective Action


Please provide valid administrator username and password to access the gateway server.










Applies to:


Siebel eClinical - Version 8.1.1.5 SIA [21229] and later
Information in this document applies to any platform.



Symptoms


After server reboot unable to start the siebel service.


Observed the below errors in NameServer.log file:


2009-09-18 16:14:49 select T2.NAME from
SIEBEL.S_PER_RESP T1, SIEBEL.S_RESP T2, SIEBEL.S_USER T3 where
T1.RESP_ID=T2.ROW_ID AND T1.PER_ID=T3.PAR_ROW_ID AND T3.LOGIN='SADMIN'

2009-09-18 16:14:49End 10 Worst Performing Queries ***********

2009-09-18 16:14:49 (SQLFreeEnv) Env Handle: 812926856, Time: 0.004ms

2009-09-18 16:14:49 Invoking SecurityGetRoles for user sadmin.

2009-09-18 16:14:49 user sadmin has 246 responsibilities.

2009-09-18 16:14:49 (client.cpp (325) err=5043 sys=0) SBL-GEN-05043: The
specified user does not have the proper privileges to connect to the
name server.




Cause


SADMIN user got deleted.





Solution


After restoring the SADMIN user and restarting the gateway along with Siebel server resolved the issue.




References


NOTE:944161.1 - RECEIVING ERROR MESSAGE WHEN STARTING THE SIEBEL SERVER OR SRVRMGR












Symptoms



Siebel 8.1.1 new installation was working fine.
After migrate database from previous Siebel version, gateway was starting, but srvrmgr was not working.


Cause


We have verified SADMIN was correctly connecting to database from Gateway machine.


Solution



We checked all DB2 settings and connection were working from Gateway.
But we still had this error message in the gateway log:

2009-09-18
16:14:49 select T2.NAME from SIEBEL.S_PER_RESP T1, SIEBEL.S_RESP T2,
SIEBEL.S_USER T3 where T1.RESP_ID=T2.ROW_ID AND T1.PER_ID=T3.PAR_ROW_ID
AND T3.LOGIN='SADMIN'
2009-09-18 16:14:49End 10 Worst Performing Queries ***********
2009-09-18 16:14:49 (SQLFreeEnv) Env Handle: 812926856, Time: 0.004ms
2009-09-18 16:14:49 Invoking SecurityGetRoles for user sadmin.
2009-09-18 16:14:49 user sadmin has 246 responsibilities.
2009-09-18
16:14:49 (client.cpp (325) err=5043 sys=0) SBL-GEN-05043: The specified
user does not have the proper privileges to connect to the name server.
2009-09-18 16:14:49 515: [TCPIP-server] recv() failed for sd=-1 (err=9 | Bad file number)
2009-09-18 16:14:49 515: [TCPIP-server] send() failed for sd=-1 (err=9 | Bad file number)


Running
the above query against both the custom and vanilla databases showed
that the Siebel Administrator Reponsability was missing. It existed for
other users but was missing for Sadmin user. After adding the Siebel
Administrator to the SADMIN user, the Gateway started correctly and
srvrmgr ran correctly.





 