SBL-SEC-10001: An internal error has occurred within the authentication subsystem for the Siebel App.





Applies to:


Siebel System Software - Version 8.0 [20405] and later
Information in this document applies to any platform.

***Checked for relevance on 27-SEP-2012***


Symptoms


When using the LDAPSecAdpt to authenticate against an Active
Directory server with the BaseDN set to the root level, the Siebel
application will not come up.  Examination of the Security Adapter logs
shows an error pattern similar to the following when trying to search
for the UserDN:


SecAdptLog API Trace 4 000000084a7719a0:0 2009-08-03 16:38:07 Ldap
Utility: GetUserDn. Username=ANONUSER, Attribute=sAMAccountName,
BaseDN=DC=xxxx,DC=xxxx

SecAdptLog 3rdpartyTrace 3 000000084a7719a0:0 2009-08-03 16:38:08
ldap_search_s(1094aa0, DC=thcg,DC=net, LDAP_SCOPE_BASE,
(sAMAccountName=ANONUSER), ...) returns 1.

SecAdptLog 3rdpartyTrace 3 000000084a7719a0:0 2009-08-03 16:38:08 ldap_msgfree (10957f8)

SecAdptLog 3rdpartyTrace 3 000000084a7719a0:0 2009-08-03 16:38:08 ldap_unbind(1094aa0) returns 0.

SecAdptLog Memory Mgmt Trace 5 000000084a7719a0:0 2009-08-03 16:38:08 LDAP SecurityFreeErrMessage8, ErrMessage=c822828.

GenericLog GenericError 1 000000084a7719a0:0 2009-08-03 16:38:08
(secmgr.cpp (2486) err=4597538 sys=0) SBL-SEC-10018: Operations error

GenericLog GenericError 1 000000084a7719a0:0 2009-08-03 16:38:08
(secmgr.cpp (2558) err=4597521 sys=0) SBL-SEC-10001: An internal error
has occurred within the authentication subsystem for the Siebel
application. Please contact your system administrator for assistance.

ObjMgrSessionLog Error 1 000000084a7719a0:0 2009-08-03 16:38:08
(physmod.cpp (9244)) SBL-DAT-00565: An internal error has occurred
within the authentication subsystem for the Siebel application. Please
contact your system administrator for assistance.

ObjMgrSessionLog Error 1 000000084a7719a0:0 2009-08-03 16:38:08
(model.cpp (5886)) SBL-DAT-00565: An internal error has occurred within
the authentication subsystem for the Siebel application. Please contact
your system administrator for assistance.

ObjMgrCTLog Error 1 000000084a7719a0:0 2009-08-03 16:38:08 (ctxtmgr.cpp (4493)) SBL-SVC-00208: Please login first.



Cause


This behavior is being caused by how the LDAPSecAdpt, IBM LDAP Client
libraries, and the Windows 2003 based Active Directory are interracting
when the BaseDN is set to the root level. The fundamental issue is that
Windows 2003 introduced stricter authentication/authorization
requirements when attempting to access certain parts of the overall
schema and resources.



When you do an LDAP search from the root of the Active Directory, you
are searching everything under the root. This includes not only things
like Organizational Units, Computers, etc.; but also fundamental
configuration and schema entities such as:



DC=Configuration,DC=domain,DC=net

DC=DomainDnsZones,DC=domain,DC=net



It is the fact that the application user does not have adequate access to these types of entities that is causing the behavior.



Solution


This behavior is due to the fact that the LDAPSecAdpt is attempting
to search hidden/system containers to which it does not have access.
Since you are not using PropagateChange=True to make changes to the AD
from the Siebel application and the Active Directory in question has
Global Catalog functionality enabled, the best workaround at this time
is to point the LDAPSecAdpt to the Global Catalog port of 3268.



1. Login to an employee facing, high interactivity Siebel application (e.g. Sales, Call Center, etc.) as an administrator.



2. Navigate to Site Map > Administration - Server Configuration > Enterprises > Profile Configuration.



3. Make sure the correct Siebel Enterprise is selected in the top applet.



4. In the middle applet query for LDAPSecAdpt (or whatever name you have given your LDAP Security Adapter).



5. In the bottom applet find the Port parameter and change it to 3268.



6. Step off to save the change and logout of the Siebel application.



7. Stop and restart the Siebel Server service(s) and the Siebel Gateway service.



There are limitations when using the Global Catalog with Siebel. In
summary, you have to set the PropagateChange parameter on the
LDAPSecAdpt to False. This means you will not be able to update anything
in the Active Directory (for example passwords) from the Siebel
application. For more in-depth information, please see the following on
My Oracle Support:



"ADSI Authentication Using Global Catalog Port 3268 (Doc ID 517259.1)"



"With Windows Integrated Authentication based SSO, can we have users from multiple domains? (Doc ID 834759.1)"





If you require PropagateChange = True in your implementation, then
the Global Catalog workaround above will not work.  There are several
options in this case:



  1. If your Siebel application servers are running on a Windows operating system, you could switch to the ADSISecAdpt.




  2. Drop the BaseDN down one level.  It is important that all the Siebel
    users (including the anonymous user in eapps.cfg) be in or under the
    BaseDN your specify.




  3. Make the application user specified in the LDAPSecAdpt's
    ApplicationUser parameter a Domain Administrator within the Active
    Directory.









Applies to:


Siebel CRM - Version: 8.1.1 [21112] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms


Customer is unable to see the login screen and the following errors are found in the OM log:
SecAdptLog API Trace 4 000000034d3520f3:0 2011-01-18 15:11:32 DB SecurityLogin with username=SADMIN, parameters=3ae0e00.
SecAdptLog Debug 5 000000034d3520f3:0 2011-01-18 15:11:32 DB security adapter: Load data source configuration
ObjMgrDBConnLog
Create 5 000000034d3520f3:0 2011-01-18 15:11:33 DataBase Connection
Object was created at 3cdeb90; DB User: 'SADMIN'
ObjMgrLog Error 1
000000034d3520f3:0 2011-01-18 15:11:33 (oracon.cpp (3122))
SBL-DBC-00107: An Oracle database error has occurred.
Please continue or ask your systems administrator to check your application configuration if the problem persists.
SecAdptLog
API Trace 4 000000034d3520f3:0 2011-01-18 15:11:33 Security DB user
connect to DB CRM with username=SADMIN returns err 65535 and connection
3cdeb90.
SecAdptLog API Trace 4 000000034d3520f3:0 2011-01-18 15:11:33 Security DB user delete DB connectoin 3cdeb90
ObjMgrDBConnLog Delete 5 000000034d3520f3:0 2011-01-18 15:11:33 DataBase Connection was deleted at 3cdeb90
GenericLog
GenericError 1 000000034d3520f3:0 2011-01-18 15:11:33 (secmgr.cpp
(2676) err=4597538 sys=0) SBL-SEC-10018: An Oracle database error has
occurred.
Please continue or ask your systems administrator to check
your application configuration if the problem persists.(SBL-DBC-00107)

SecAdptLog Memory Mgmt Trace 5 000000034d3520f3:0 2011-01-18 15:11:33 DB SecurityFreeErrMessage, message=<?INT?>.
GenericLog
GenericError 1 000000034d3520f3:0 2011-01-18 15:11:33 (secmgr.cpp
(2750) err=4597521 sys=0) SBL-SEC-10001: An internal error has occurred
within the authentication subsystem for the Siebel application. Please
contact your system administrator for assistance.
ObjMgrSessionLog
Error 1 000000034d3520f3:0 2011-01-18 15:11:33 (physmod.cpp (9330))
SBL-DAT-00565: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.
ObjMgrSessionLog Error 1
000000034d3520f3:0 2011-01-18 15:11:33 (model.cpp (5890)) SBL-DAT-00565:
An internal error has occurred within the authentication subsystem for
the Siebel application. Please contact your system administrator for
assistance.
ObjMgrSessionLog ObjMgrLogin 3 000000034d3520f3:0 2011-01-18 15:11:33 Login failed for Login name : SADMIN


Cause


During the investigation, the customer confirmed that they are able to
connect using sqlplus and odbcsql with the SADMIN credentials. However,
the login page does not appear.

Subsequent investigation reveals
that customer has installed an Oracle DatavaseInstant Client instead of a
full version of the Oracle database client software.


Solution


1. Request customer to download the 'Oracle Database 11g Release 2 Client (11.2.0.1.0) for HP-UX Itanium

hpia64_11gR2_client32.zip (32-bit)' from
http://www.oracle.com/technetwork/database/enterprise-edition/downloads/112010-hpisoft-097214.html

2. Install the Oracle client package and set the SHLIB_PATH before restarting the Siebel Services


References


NOTE:476703.1
- What Are the Steps To Troubleshoot the Error Message: The Server You
Are Accessing is Either Busy or Experiencing Difficulties...in a Siebel
Web Client User Browser?

NOTE:1085793.1
- Servers won't start; gateway throws error: "Fatal error (2555922):
Could not open connection to Siebel Gateway configuration store










Applies to:


Siebel Communications CRM Call Center, SPE - Version: 8.1.1 SIA [21111] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms


After installing SIA 8.1.1 on Oracle 10.2.0.4 database, customer
found that they are unable to connect using web client. In the OM logs,
we found the following errors:



SecAdptLog API Trace 4 0000000449be4182:0 2009-03-16 17:36:01 DB SecurityLogin with username=sadmin, parameters=3ab1210.
SecAdptLog Debug 5 0000000449be4182:0 2009-03-16 17:36:01 DB security adapter: Load data source configuration
SecAdptLog
Debug 5 0000000449be4182:0 2009-03-16 17:36:01 DB security adapter:
Could not load or initialize data source ServerDataSrc, err=65535.
SecAdptLog API Trace 4 0000000449be4182:0 2009-03-16 17:36:01 Security DB user delete DB connectoin 0
GenericLog
GenericError 1 0000000449be4182:0 2009-03-16 17:36:01 (secmgr.cpp
(2676) err=4597538 sys=0) SBL-SEC-10018: Can't load
sscdo90(SBL-GEN-02500)
..
GenericLog GenericError 1
0000000449be4182:0 2009-03-16 17:36:01 (secmgr.cpp (2750) err=4597521
sys=0) SBL-SEC-10001: An internal error has occurred within the
authentication subsystem for the Siebel application. Please contact your
system administrator for assistance.
ObjMgrSessionLog Error 1
0000000449be4182:0 2009-03-16 17:36:01 (physmod.cpp (9330))
SBL-DAT-00565: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.
ObjMgrSessionLog ObjMgrLogin 3 0000000449be4182:0 2009-03-16 17:36:01 Login failed for Login name : sadmin



Cause


It was found that the customer was using Oracle 10g client, which is not supported with Siebel 8.1.1 - please check Siebel System Requirements and Supported Platforms Documentation for details.



Solution


The customer was advised to install a supported Oracle 11g client,
however after installing Oracle 11.1.0.6 client, the lib32
(32-bit libraries) directory was not present. This is a known issue for
this client version on HP-UX Itanium:
see Document 471476.1 for more details.



To workaround the behavior, customer installed Oracle 11.1.0.7 database client.








Applies to:


Siebel CRM - Version 8.1.1 SIA [21111] and later
Information in this document applies to any platform.


Symptoms


1) Gateway Server is running on Node A and the Siebel Server  is running on Node A. No Problems.

2) Take offline the Siebel Server on Node A

3) Take offline the Gateway Server on Node A

4) Move the Gateway Server to Node B, and have it online

5) Bring online the Siebel Server on Node A, it fails

6) Move the Gateway Server back to Node A

7) Bring online the Siebel Server on Node A, it works



Cause


All Siebel Servers installed into an Enterprise Server use the same
ODBC data source, including the Gateway Server service since the Siebel
version 8.1.x. The name for the ODBC data source is
<enterprise_name>_DSN; this is the format used since the Siebel
version 8.0.x.



In the customer environment, the Gateway Server was installed on g:\
drive, and the Siebel Server installed on the h:\ drive. Both
installations were done while in the same Node A.



The ODBC data source which was last created was the one produced by the
Siebel Server installation, which overwrote the initial ODBC data source
produced by the Gateway Server installation.



Under this condition, the ODBC data source driver which driver is
located under the Siebel Server installation directory will not
available when the two resources are not running on the same node as the
ODBC driver used by the Gateway Server is pointing to the driver
located under the Siebel Server installation.



In the nameserver_audit.log that there was an error message saying that
authentication was failing, and there was another error saying that
driver could not be loaded.



In the nameserver.log the following error messages were found:



GenericLog GenericError 1 0000000c4b1f1808:0 2009-12-09 11:35:01
(secmgr.cpp (2679) err=4597538 sys=0) SBL-SEC-10018: data source connect
string or table owner is empty.



GenericLog GenericError 1 0000000c4b1f1808:0 2009-12-09 11:35:01
(secmgr.cpp (2751) err=4597521 sys=0) SBL-SEC-10001: An internal error
has occurred within the authentication subsystem for the Siebel
application. Please contact your system administrator for assistance.











Solution


In order to resolve the issue it is necessary to re-run the Siebel
Enterprise Configuration wizard to recreate the ODBC DSN for the Gateway
Server service. However, this can be only executed once during the
initial installation.



Follow the steps below to recreate the ODBC DSN used by the Gateway
Server service, and make the necessary changes to have two independent
ODBC DSNs:



1) Have the Gateway Server service and Siebel Server service moved to the same node where both services can run without issues

2) Make sure both services are stopped

3) Rename the siebns.dat to siebns.old, and take a backup copy for safety reasons

4) Download the empty siebns.dat <<emptysiebns>> attached to
this document, rename it to siebns.dat, and place it in the Gateway
Server installation

5) Start the Gateway Server service

6) Execute the Siebel Enterprise Configuration wizard, and choose Configure Product in Live Mode

    6.1) Choose Create New Configuration and click Next

    6.2) Choose Configure a New Enterprise in a Gateway Name Server

    6.3) Provide the parameters as initially informed when the
Enterprise was first configured, but inform a different Enterprise name,
for example, dummy. If you provide the same Enterprise name, the
already existing ODBC DSN for the Siebel Server will be overwritten.

7) Go to Administrative Tools > Data Sources (ODBC), click on System
DSN tab, and choose the ODBC DSN which was created by the wizard on step
6. Following the example, if you entered dummy as the Enterprise name,
you should find dummy_DSN in the System DSN tab.

8) Click on Configure button, rename the ODBC DSN to <enterprise name>_GTWY_DSN, for example: SBA_81_GTWY_DSN

9) Stop the Gateway Server service

10) Delete the siebns.dat created on step 6 above.

11) Rename the siebns.old (see step 3) to siebns.dat

12) Open the gateway.cfg file located under the gtwysrvr/bin directory
with a text editor, and modify the ConnectString in the [ServerDataSrc]
section to match the ODBC DSN name defined by you on step 8

13) Export the following registry keys and import them into the other cluster nodes:



HKEY_LOCAL_MACHINE\SOFTWARE\ODBC\ODBCINST.INI\Siebel Oracle90 <gateway server installation root directory>



HKEY_LOCAL_MACHINE\SOFTWARE\ODBC\ODBC.INI\<ODBC DSN Name as set on step 8>



--



The Bug 10643382 has been logged to have the ODBC DSN creation in the cluster_gtwy.bat



Please note, you can rename the ODBC DSN as described above after the
Gateway Server creation and before the Siebel Server configuration.
These are the two points where the ODBC DSN are created; the latter
Siebel Server configuration will overwrite the ODBC DSN created for the
Gateway Server.














Applies to:


Siebel System Software - Version: 8.1.1.1 SIA [21211] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms



In Siebel 8.1, customer was attempting to authenticate with external
security adapter authentication (LDAPSecAdpt or ADSISecAdpt). The
process was failing in the bind stage with the following error pattern:



Ldap Utility: BindAsAppUser failed due to invalid password, please check the value of ApplicationPassword parameter,



SBL-SEC-10001: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.

SBL-DAT-00565: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.

SBL-DAT-00565: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.

Login failed for Login name : XXXXXX




Cause


There are two common causes of this error.

1.  The password
specified in the ApplicationPassword parameter in your security adapter
profile does not match the password for the application user (specified
in the ApplicationUserDN parameter) in the LDAP or Active Directory
server.

2.  The value specified for the ApplicationUserDN parameter does not match a valid user in your LDAP or Active Directory server.


Solution



If the cause is a password mismatch, the solution is to simply
update the ApplicationPassword parameter with the correct password.  In
most cases you will not even need to restart the services.  You will
just need to create a new clean connection with a new session.

If
the cause is an invalid user, first check for typographical errors done
when entering the ApplicationUserDN parameter value.  If present,
correct the errors and test the behavior again.

If the issue is
not a typographical error, you will need to confirm the actual fully
qualified designated name (DN) of the application user in the external
directory.  This is the unique value that identifies a given entry in
the external directory server and its format can vary depending on
external directory used and the configuration of the directory.  To
determine the actual DN for an entry, check with your directory
administrator or view the entry using a third party LDAP browsing tool.

The most common format for DNs on Active Directory looks similar to:

cn=Any User,ou=Siebel,dc=Fake,dc=Oracle,dc=com

With
LDAP directories, there is often more flexibility as to what the fields
are names and to which field forms the "key" field for determining the
DN.  Some examples:

uid=Any User,cn=Siebel,o=Fake,o=Oracle.com
cn=Any User,ou=Siebel,dc=Fake,dc=Oracle,dc=com
sn=AUSER,cn=Siebel,o=Fake.Oracle.com

As
you can see, the only real way to determine the correct DN is to verify
the value in the Directory Server.  Normally your Active Directory or
LDAP administrator can assist you with this, but if further assistance
is necessary please open a service request through My Oracle Support.








Applies to:


Siebel CRM Call Center - Version: 7.8 [19021] to 7.8 [19021] - Release: V7 to V7
IBM AIX on POWER Systems (64-bit)

Product Release: V7 (Professional)

Version: 7.8.2.2 [19219]

Database: IBM DB2 8.2

Application Server OS: IBM AIX 5L 5.2

Database Server OS: IBM AIX 5L 5.2



This document was previously published as Siebel SR 38-3070043331.



Symptoms


SBL-SEC-10018

I'm unable to access the system through the dedicated client. When I
attempt to login I get an 'Invalid username/password error'.

I've checked the siebel.log produced when I get the error and this gives the following:

2021
2006-06-20 09:10:10 0000-00-00 00:00:00 +0100 00000000 001 003f 0001 09
siebel 912 1168 C:\Program Files\Siebel\7.8\web client\log\siebel.log
7.8.2 [19213] ENU

GenericLog    GenericError    1    0    2006-06-20
09:10:10    (secmgr.cpp (2357) err=7010018 sys=1717) SBL-SEC-10018:
Can't load sscddcli.dll(SBL-GEN-02500)


GenericLog    GenericError    1    0    2006-06-20
09:10:10    (secmgr.cpp (2429) err=7010001 sys=0) SBL-SEC-10001: An
internal error has occurred within the authentication subsystem for the
Siebel application. Please contact your system administrator for
assistance.



Cause


The Siebel error messages were caused by a compatibility issue between
the Datawatch QSM software and the IBM DB2 Client software.


Solution



For the benefit of other users, the customer installed
Visual|QSM Service Management software from Datawatch Corporation
(www.datawatch.com) and began receiving the following error messages
when attempting to logon to the Server datasource through either the
Siebel Client or Siebel Tools:

SBL-SEC-10001: An internal error
has occurred within the authentication subsystem for the Siebel
application. Please contact your system administrator for assistance.

SBL-SEC-10018: Can't load sscddcli.dll(SBL-GEN-02500)

Summary:

Further
research found logging in to the Local or Sample datasources through
either the Siebel Client or Siebel Tools worked, implying the error
messages being returned were caused by database connectivity issues.

We
attempted to configure the Server ODBC source through the Windows ODBC
Data Source Administrator utility and the window that appeared was
similar to the Add ^ Create a New Data Source ^ IBM DB2 Driver window.


The default IBM DB2 datasource configuration window that
should appear contains two tabs titled ‘Data Source’ and ‘Advanced
Settings’.


The expected IBM DB2 driver configuration window re-appeared after re-installing the IBM DB2 Client Software.

Therefore,
the Siebel error messages were caused by a compatibility issue between
the QSM software and the IBM DB2 Client software which adversely
affected Siebel when attempting to make a database connection.













Applies to:


Siebel System Software - Version: 8.0 [20405] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms


Customer reported the following:

It is not possible to log on to
the Siebel CRM application using a Siebel Dedicated Web Client on one of
the Application Servers in his Siebel environment. He changed all the
parameters in the Siebel dedicated client CFG file found in
WebClient\BIN\ENU folder.
There is no encryption software used.

From the log, the following errors were found:
GenericLog
GenericError 1 000000024a6f0a10:0 2009-07-29 15:23:31 (secmgr.cpp
(2486) err=4597538 sys=127) SBL-SEC-10018: Can't load
sscddcli.dll(SBL-GEN-02500)

GenericLog GenericError 1
000000024a6f0a10:0 2009-07-29 15:23:31 (secmgr.cpp (2558) err=4597521
sys=0) SBL-SEC-10001: An internal error has occurred within the
authentication subsystem for the Siebel application. Please contact your
system administrator for assistance.

ObjMgrSessionLog Error 1
000000024a6f0a10:0 2009-07-29 15:23:31 (physmod.cpp (9244))
SBL-DAT-00565: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.


Cause



The cause must could be related to the incorrect setting in the application .cfg file:
[ServerDataSrc]
DLL = sscddcli.dll

This is not correct for Oracle RDBMS, it should be sscdo90.dll


[ServerDataSrc]
DLL = sscdo90.dll

incorrect dll settings in the Siebel dedicated client CFG file will cause failures to connect to the Siebel database.


Solution


For the benefit of other readers:

After changing the application CFG:
[ServerDataSrc]
DLL = sscddcli.dll

to

[ServerDataSrc]
DLL = sscdo90.dll

Customer was able to connect using the Siebel dedicated web client.











Applies to:


Siebel System Software - Version: 7.7.2 [18325] and later   [Release: V7 and later ]
Information in this document applies to any platform.

Product Release: V7 (Enterprise)

Version: 7.7.2 [18325]

Database: Oracle 9.2.0.0

Application Server OS: Microsoft Windows 2003 Server SP2

Database Server OS: Microsoft Windows 2003 Server SP2



This document was previously published as Siebel SR 38-3330680661.



Symptoms


SBL-SEC-10001We just installed 77 base software and we are noticing the attached errors on the object
managers. There were no errors during the installation. When the thin client was not coming up,
we tried to login through the dedicated web client and through tools and were getting the
following error.
SBL-SEC-10001: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system administrator for
assistance.

We are able to connect through the oracle sql plus client and also validate
the db connectivity using tnsping without any errors. We are having this issue only when
connecting through Siebel and none of the object managers are coming up.

Any help ASAP
would help us a lot since we are on a very tight schedule and this needs to be resolved at the
earliest.

Thank you






Cause


Configuration/ Setup


Solution



Message 1


                                                                                                  
*** For the benefit of others ***



After installing Siebel Server 7.7 base and then trying to logon via the dedicated client, the following error was encountered:

SBL-SEC-10001: An internal error has occurred within the authentication
subsystem for the Siebel application. Please contact your system
administrator for assistance.



Siebel.log also contained these errors:

SecAdptLog    API Trace    4    0    2007-04-22 21:54:49    DB SecurityLogin with username=sadmin, parameters=581b7d0.

SecAdptLog    Debug    5    0    2007-04-22 21:54:49    DB security adapter: Load data source configuration

ObjMgrDBConnLog    Create    5    0    2007-04-22 21:54:49    DataBase
Connection Object was created at 57ca160; DB User: 'sadmin'

DBCLog    DBCLogError    1    0    2007-04-22
21:54:49    OCIStmtExecute: ALTER SESSION SET
"_optimizer_sortmerge_join_enabled" = false

ObjMgrLog    Error    1    0    2007-04-22 21:54:49    (oracon.cpp
(3018)) SBL-DBC-00111: An error has occurred writing to a record.

Please continue or ask your systems administrator to check your application configuration if the problem persists.

SQLParseAndExecute    Execute    5    0    2007-04-22 21:54:49    ORA-02248: invalid option for ALTER SESSION



Based on research here, it was found an unsupported Database platform had been installed.

Please note that Oracle 9.2.0.0 certified for use with Siebel
Server7.7.x; at the very least upgrade the Database Server to Oracle
9.2.0.4.
















תגובות

פוסטים פופולריים מהבלוג הזה

FINS Data Transfer Utilities

SBL-BPR-00191: The rowId of the active row of the primary buscomp '%1', '%2', does not match the Primary Id

Profile Attributes and Open UI