SBL-SCC-00025: No value found in the Gateway. Default value in the repository is used.



Applies to:


Siebel System Software - Version: 7.5.3.1 SIA [16161] and later   [Release: V7 and later ]
z*OBSOLETE: Microsoft Windows 2000

Product Release: V7 (Enterprise)

Version: 7.5.3.1 [16161] Fin Svcs

Database: Microsoft SQL Server 2000 SP 2

Application Server OS: Microsoft Windows 2000 Server

Database Server OS: Microsoft Windows 2000 Advanced Server SP 2



This document was previously published as Siebel SR 38-1746031351.



Symptoms


SBL-SCC-00025, SBL-SVR-00106, SBL-SMI-00147We have two app servers load balanced with Resonate. Today around noon our application server 1
(app1) went down with a handshake error. We recycled the siebel services tonight but now the app1
server is not coming up. All server components in this server are exiting with the following
error:
Error: can't get version of installed components (ENU sia)
errors at the enterprise
log
are:
GenericLog    GenericError    1    2005-01-31
23:59:32    (schedule.cpp 17(793) err=2100096 sys=0) SBL-SMI-00096: The
maximum number of restarts (10) for MinUpTime has been reached. The component CommSessionMgr will
not be restarted again.

We searched in SupportWeb and even restored a backup of our
siebns.dat file with no avail.
I have attached all log files before and after recycling the
services.

We have configured all our objects managers and external connection to point to
app2 in the meantime, however some of the sertvices like to outbound communication manager are
not working (Communication Request) which impact our service levels to our clients. Please
contact us as soon as possible.
Thank you.






Cause


Configuration/ Setup


Solution



Message 1


For the benefits of other users:



All the components on one of the application servers, app1, were exiting
with error. Reviewed of all the components log files show the following
error messages,



GenericLog    GenericError    1    2005-01-31 23:25:28    Error: can't get version of installed components (ENU sia)



GenericLog    GenericError    1    2005-01-31 23:25:29    (smimtsrv.cpp
57(533) err=2100147 sys=0) SBL-SMI-00147: (smimtsrv.cpp 57: 533) error
code = 2100147, system error = 0, msg1 = Error: can't get version of
installed components (ENU sia), msg2 = (null), msg3 = (null), msg4 =
(null)



GenericLog    GenericError    1    2005-01-31 23:25:28    (smiutil.cpp
20(156) err=2000106 sys=0) SBL-SVR-00106: Internal:The requested
Parameter/event was not found.



Resolution:



It was found that the ENUSIA folder was missing or moved from
<SIEBEL_ROOT_DIRECTORY>/siebsrvr/bin directory in app1. After
copying the ENUSIA folder from a working application server to app1, all
the components started successfully.



The customer then tried to restart the whole environment including the
two application server. However, this time a different issue occurred.
It was the second application server, app2, that was not able to start
up. Reviewed of the siebsrvr.log showed the following error message,



GenericLog    GenericError    1    2005-02-01 05:15:12    (sccnmsys.cpp
9(1295) err=4400025 sys=0) SBL-SCC-00025: No value found in the Gateway.
Default value in the repository is used.



[More...]


Message 2


[Continue...]



The customer was advised to replace the siebns.dat with a backup copy and app2 was able to startup successfully.



Keywords: srlcver.dll SBL-SMI-00147 SBL-SCC-00025 SBL-SCC-00025






Applies to:


Siebel CRM - Version: 8.0 [20405] and later   [Release: V8 and later ]
Information in this document applies to any platform.



Symptoms


When Siebel Server service is started, following error messages are recorded in SiebSrvr.log file.

SBL-SCC-00025: No value found in the Gateway. Default value in the repository is used.
SBL-SCC-00018: Internal:The request value has never been set either from the srd repository or the backing store.
SBL-SCM-00028: Key not found

How can we resolve these messages?


Solution


Please note these messages are usually benign and can be ignored safely.








Applies to:


Siebel System Software - Version: 7.5.3 SIA [16157] and later   [Release: V7 and later ]
HP-UX Itanium

Product Release: V7 (Enterprise)

Version: 7.5.3 [16157] Cons Sec

Database: Oracle 9.2.0.2

Application Server OS: HP-UX 11i

Database Server OS: HP-UX 11i



This document was previously published as Siebel SR 38-1089773731.



Symptoms


SBL-SCC-00025Hi,

We are unable to start the siebel server.We are getting the following error .
"
SBL-SCC-00025: No value found in the Gateway. Default value in the repository is
used."

The log file is attached.

Please advice us

Regards






Cause


Change Request 12-EB349Z


Solution



Message 1


Hello,



We have traced the problem to a file system issue in Unix. One of the
file system was full which was causing our server to not start. What
took us this long was the lack of clear message in the SiebSrvr.log
file. Our server is up now but we still see errors in there. The error
what we see in the long consistently is the following below



GenericLog      GenericError    1       2003-09-26
14:13:22     (sccnmsys.cpp 9(1295) err=4400025 sys=0) SBL-SCC-00025: No
value found in the Gateway. Default value in the repository is used.



Any help on this would be greatly appreciated



Thanks



Sachin


Message 2


Sachin,



Thank you for the update.



If the Application Server runs fine, you could ignore this error
message. In other words, this error message alone is generally benign.



However, if the Application Server or Server Components could not
perform tasks as expected, you usually see this error along with other
errors in the logs.



Change Request 12-EB349Z (doumentation enhancement request) has been
raised to better document the Siebel Version 7.5.2.x error messages to
inform us that this error "SCC-00025: No value found in the Gateway.
Default value in the repository is used" is actually of a benign nature
and nothing to be concerned about.



Please let me know if you have any more questions or if we may conclude our work on this Service Request.



Thanks






Applies to:


Siebel System Software - Version: 7.5.2.7 SIA [15058] and later   [Release: V7 and later ]
z*OBSOLETE: Microsoft Windows 2000

Product Release: V7 (Enterprise)

Version: 7.5.2.7 [15058] Life Sci

Database: Oracle 9.0.1.3

Application Server OS: Microsoft Windows 2000 Server

Database Server OS: Sun Solaris 2.8



This document was previously published as Siebel SR 38-1022661651.



Symptoms


SBL-SCC-00025Hi

What was thought of a Reports issue was due to the Single sign on not
functioning.

The eapps.cfg when has a entry like below

ENABLEFQDN = TRUE
and
FQDN = webserver.companyps.com

the zero foot print is never available and the it
throws out an error called "Page cannot be displayed".

The above mentioned SR has got
attachments related to the event log.






Cause


Configuration/ Setup


Solution



Message 1


For the benefit of other readers, this Actuate Reports Service Request developed into a Web Server access request.



In the eapps.cfg file the settings:



EnableFQDN     = FALSE

FQDN         = CHANGE_ME



When this was changed to:



EnableFQDN     = TRUE

FQDN         = webserver.companyps.com



This caused the "Page cannot be displayed" error.



The SWSE Log files contained the error messages:



GenericLog    GenericLog    0    2003-06-17 17:41:00     [676] ERROR
676: [SWSE] Wrong section name [/wpsales_heb]? in config file.
<br>Error in eapps.cfg file at line 1530 <br>Error in
loading configuration!



GenericLog    GenericLog    0    2003-06-18 06:25:11     [1440]
ERROR   1440: [SWSE] Error Message 1 : error 1030 : 65*SMI-00107:
Internal: The context for the given task was not
found1*016*smimtpool.cpp 503*8290*0*0*0*





GenericLog    GenericLog    0    2003-06-18 06:25:11     [1440] ERROR   1440: [SWSE] invoke service method failed.



The corresponding Siebel Sever log file report:



GenericLog    GenericError    1    2003-06-17 18:17:15    (sccnmsys.cpp
9(1295) err=4400025 sys=0) SCC-00025: No value found in the Gateway.
Default value in the repository is used.



GenericLog    GenericError    1    2003-06-17 18:17:15    (sccnmsys.cpp
9(1295) err=4400025 sys=0) SCC-00025: No value found in the Gateway.
Default value in the repository is used.



It was found that the cause of the errors following the FQDN changes were due to Resonate.



(continued)


Message 2


The settings were changed in Resonate under 'Site Setup > Operations
> Advanced', the heartbeat was increased from '5' to '60' and this
enabled the Web Client to function.







-Siebel Technical Support



Keywords: EnableFQDN, FQDN, Resonate, heartbeat, SCC-00025, eapps.cfg,
ERROR 676, ERROR 1440, Page cannot be displayed, wpsales_heb, Actuate




תגובות

פוסטים פופולריים מהבלוג הזה

FINS Data Transfer Utilities

SBL-BPR-00191: The rowId of the active row of the primary buscomp '%1', '%2', does not match the Primary Id

Profile Attributes and Open UI